MENSI Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit with ?/?" ???? ????? ?????? (?/?"-??????) Fitting

MENSI Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit with ?/?" ???? ????? ?????? (?/?"-??????) Fitting

Product ID: B07CN33GSJ Condition: New

Payflex: Pay in 4 interest-free payments of R383.00. Read the FAQ
RΒ 1,532
includes Duties & VAT
Delivery: 10-20 working days
Ships from USA warehouse.
Secure Transaction
VISA Mastercard payflex ozow

Product Description

MENSI Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit with ?/?" ???? ????? ?????? (?/?"-??????) Fitting

  • Low Working Pressure Max 1/2 PSI(65mbarοΌ‰, CE&CSA tested Main Control Valve In & Out with πŸ‘/πŸ–" 𝐌𝐚π₯𝐞 𝐅π₯𝐚𝐫𝐞 π’π°π’π―πžπ₯ (πŸ“/πŸ–"-πŸπŸ–π”ππ„π…) thread
  • Length of Thermocoupler 600mm Head Tip M8*1 (This is Low pressure control valve max rating BTU 50000)
  • Platic Black Bakelite Knob Diameter 38mm and "D" Insert for Valve 6.0-6.1mm
  • Suitable for Low Pressure Repair Control System for Grill, Fire Pit, Fireplace & Heater (max BTU rating: 50000 working pressure 65mbar)
  • Keep The Thermocoupler to be Heated and Push the Valve around 5-10s Then Release Hand (if Flame stops, Ajust the location of Thermocouple tip)

The valve is a low pressure valve with 3/8" Male flare thread on Entrance & Exit
Operation Instructions
1). Fix the valve on a plate or board of your grill or fire pit by the head screw and flange.
2). Connect your inlet and outlet hose on inlet and outlet side. (faston it tightly enough in case of gas leakage)
3). Faston the thermocouple nut M8 on the valve end tightly (Check if your valve end thread if 8mm before you buy)
4). Connect thermocouple and end thread well
5). Open gas by correct size knob and push your valve around 5-10s till the thermocouple head is heated enough.
6). Release your hand and it work properly If when you release hand, gas valve shut off again, Please check
a. If your thermocouple is always be heated on flame
b. If the thermocouple end is well connect with valve
c. If the inlet and outlet side well connect with hose you have
Possible problems occurs during your use:
1) Valve after turn can not stick during using
reason: a. The thermocouple head is not heated in right place, please adjust thermocouple tip position.
b. The connection between thermocouple end and valve is not connected tight enough or too tight, please adjust the screw again
c. Need to push valve first then turn the spindle and hold for few seconds, it cannot stick immediately may need 10-30Seconds

Technical Specifications

Country
USA
Brand
MENSI
Manufacturer
MNS
Binding
Lawn & Patio
ItemPartNumber
FD90 MADE OF FRD CSA Contract NO.268815
Color
Gas Valve Thermocouple Assembly
Size
5/8-18UNF male flare
UPCs
737123200474
EANs
0737123200474